MapReduce服务 MRS-Host健康检查指标项说明:硬件状态
硬件状态
指标项名称:硬件状态
指标项含义:检查系统硬件状态,包括CPU、内存、磁盘、电源、风扇等。该检查项通过ipmitool sdr elist获取相关硬件信息。如果相关硬件状态异常,则认为不健康。
恢复指导:
- 登录检查结果不健康的节点。执行ipmitool sdr elist查看系统硬件状态,命令输出的最后一列表示对应的硬件状态。如果提示的状态在下面的故障描述表中,则任务不健康。
模块
故障描述
Processor
IERR
Thermal Trip
FRB1/BIST failure
FRB2/Hang in POST failure
FRB3/Processor startup/init failure
Configuration Error
SM BIOS Uncorrectable CPU-complex Error
Disabled
Throttled
Uncorrectable machine check exception
Power Supply
Failure detected
Predictive failure
Power Supply AC lost
AC lost or out-of-range
AC out-of-range, but present
Config Error: Vendor Mismatch
Config Error: Revision Mismatch
Config Error: Processor Missing
Config Error: Power Supply Rating Mismatch
Config Error: Voltage Rating Mismatch
Config Error
Power Unit
240VA power down
Interlock power down
AC lost
Soft-power control failure
Failure detected
Predictive failure
Memory
Uncorrectable ECC
Parity
Memory Scrub Failed
Memory Device Disabled
Correctable ECC logging limit reached
Configuration Error
Throttled
Critical Overtemperature
Drive Slot
Drive Fault
Predictive Failure
Parity Check In Progress
In Critical Array
In Failed Array
Rebuild In Progress
Rebuild Aborted
Battery
Low
Failed
- 如果该指标项异常,建议联系运维人员解决处理。